For Innovative Permanent and Temporary Sheet Piling Solutions in the UK and Eire call: 01772 794141



| Contract No: | C832 |
| Client: | Tarmac National Contracting |
| Location: | A406 North London |
| Value: | Approximately £400,000.00 |
| Summary: | Design, supply, installation of steel sheet piles to form 2 No permanent highway retaining walls. The first wall consisted of 305 No piles (252 No at 10m long and 53 No at 8.0m long) and the second wall consisted of 66 No piles at 6.0m long to retain a maximum height of 2.60m. Once the sheet piles had been installed a concrete capping beam was cast on top of the piles onto to which a highway parapet barrier was fixed prior to backfilling with clean compacted granular fill behind the wall (Concrete, Barrier and Backfilling by others). |
| Drawing Ref: | Permanent Highway Retaining Wall Plan, Sections & Detail |
Sheet Piling UK Ltd were employed by Tarmac National Contracting PLC for the design and construction of permanent steel sheet pile retaining walls of 183 Lin/m and 39.6 Lin/m long, to allow earthworks widening work to be carried out in relation to junction improvements on the A 406 in North London The sheet piles were supported by the capping beam at the top.
In total 371 no. NSP.3W/ VL 606A sheet piles at lengths between 6.0m and 10.0m long were installed using a Giken SW100 Silent Piler with Water Lubrication and Full GRB System including Clamp Crane and Pile Transporter. The use of this system meant that the sheet piles could be installed without the need to close down any traffic lanes on the A 406 during the pile installation. The specialised GRB system is particularly suited to infrastructure structure works since it allows pile installation adjacent to 'live' carriageways or railway lines with little or minimal disruption. Further details on the system can be found at our web site www.sheetpilinguk.com
The general ground profile consisted of Made Ground over Firm becoming Stiff London Clay and the sheet piles were installed using minimal water lubrication provided by the Giken Super Jet Reel System. The sheet piled retaining wall was designed in strict accordance with the submitted 'Approval in Principle' documents for Highways Approval and an independent in-house category II design check was also completed.
Further more due to the new highways agency directive, the scheme was designed fully in accordance with the current Eurocode Standards including provision for Vehicular Impact Barrier Loadings.
Copyright © 2010 Sheet Piling (UK) Limited. All rights reserved. All photographs, images, logos, graphics, and designs are the property of Sheet Piling (UK) Limited. View our Privacy Policy. Creative Web Design Preston by Quentin James Design.
